Cleaning the gas
nozzle tip and
nozzle fitting - de-
tailed description
NOTE!
During the cleaning operation, blow out the welding torch with compressed air
through the hosepack - any remaining dirt or parting agent is removed.
NOTE!
Ensure that the gas nozzle does not
touch the housing components of the
cleaning opening at any time.
Position the welding torch approxima-
tely 50 mm (1.97 in.) centrally above
the middle of the cleaning opening
Move the welding torch vertically into
the cleaning/spray position
- see figure
Begin cleaning and wait for approxima-
tely 1 second
Spraying parting
agent - detailed
description
Applying parting agent evenly has the following advantages:
- reduced welding spatter accumulation
- prevents re-soiling
NOTE!
Ensure that the gas nozzle does not touch the housing components of the cleaning
opening at any time.
Maintain cleaning/spray position
- see figure
NOTE!
During the spraying process, ensure
that compressed air is not blown out
through the welding torch.
Spray welding torch with parting agent
for approximately 0.7 seconds
Move the welding torch to the start position above the cleaning opening - approximate-
ly 50 mm (1.97 in.) centrally above the middle of the cleaning opening
- The cleaning operation is complete and the welding torch is ready for use again
55 mm
(2.17 in.)
1
2
3
55 mm
(2.17 in.)
1
2
3