22
Magnetic flux
densities within
the cleaning coil
for Robacta TC
2000, Robacta TC
2000 US
Depending on the application, the strength of the magnetic flux density on the individual
areas of the welding torch can be controlled by regulating how deeply the welding torch is
immersed in the cleaning coil.
NOTE!
When using the cleaning device, refer to the program sequence for details of the
welding torch immersion depth.
Cleaning coil
Diagram showing available
magnetic flux density
Immersion depth of
torch neck into clean-
ing coil
0 % 100 %
50 mm
1.97 in.
10 mm
0.39 in.
15 mm
0.59 in.