32
Controls, connections and mechanical components
General All functions of the cleaning unit are activated by the robot control. For adjustment, the
cleaning operation can be manually triggered on the control panel.
NOTE!
The individual illustrations may differ slightly from your device.
However, the functioning of the controls and the connections is identical.
Control panel
No. Function
(1) Mains voltage indicator
lights up when the device is powered by mains voltage
NOTE!
If the capacitors in the device are charged, they will discharge automatically as soon
as the device is unplugged from the mains.
Discharge time is approx. 1 second.
(2) Overtemperature indicator
lights up when the device overheats
NOTE!
One more cleaning operation can be carried out after this indicator lights up.
Only once the device has cooled back down to the operating temperature will the device
recharge in preparation for the next cleaning operation.
(3) Fill level indicator
will come on
- if the fill level in the dipping bowl drops below minimum
- if the dipping bowl is not used, hence there is no parting agent in the dipping bowl