35
EN
- Time (hh:mm:ss)
Time zone
Daylight saving time/normal time
- Date (dd:mm:yy)
- AC current limiter
- Length of charging lead (m)
- Charging lead cross-section (mm
2
)
- Code for accessing the configuration menu activated/deactivated.
- Time interval for the parameters recorded on the USB flash drive (s).
“Reset Settings”
- Includes a double-check prompt ("OK?") that requires the operator to reconfirm that
this step is intended.
First the screen will appear in its initial for-
mat, showing the date, time and software
version.
The "Up/Down" keys can be used to retrieve the following information:
- Serial number of the charger plus serial number and version of the configuration
memory.
- PC board for controller/power electronics: hardware version and serial number.
- Software: main software, secondary software, primary software and characteris-
tic block version.
The procedure for opening the configuration menu is as follows:
Press the "Pause/Start" key.
You will be prompted to enter a code.
The code required is "1511" and is entered
as follows:
Using the "Up/Down" keys, enter the first digit of the code.
Press the "Menu" key to move to the next digit of the code.
Continue following the procedure described above until the complete code has been
entered.
Use the "Pause/Start" key to confirm the code entered.
1
1
2
4