Special charges Special Charges
Selecting "Special Charges" allows one or
more of the alternative charging types to be
performed temporarily.
The "repeat" setting defines how often the alternative charging mode should be performed
until the device reverts to the original charging parameters again:
Setting range
- 1 to 99 repetitions
Disable Start Button
ON
- The charging process cannot be started using the "Pause/Start" key, e.g. to prevent
unauthorised intervention.
OFF
- The charging process can be started using the "Pause/Start" key.
The following settings are also possible:
- Characteristic:
e.g. "Deep discharge 10"
- Number of battery cells:
"Cells" - e.g. 12x
- Battery capacity in Ah:
e.g. 375 Ah
“Opportunity
Charge” special
function
"Opportunity Charge” special function:
To extend the usage interval of a battery, it
is possible to recharge it at a time when it
will not be needed, e.g. during scheduled
plant shutdowns.