61
EN
Selectiva 3 kW
Mains voltage
1)
~ 230 V, ± 15%
Grid frequency 50/60 Hz
Mains fuse protection
2)
max. 16 A
Minimum mains lead cross section 1.5 mm² (0.002325 in.²)
Protection class I (with ground conductor)
Max. permitted mains impedance Z
max
on PCC
3)
None
Standby consumption
24 V devices
48 V devices
4.9 W
5.1 W
EMC device class B
Dimensions L x W x H 417 x 110 x 198 mm
(16.42 x 4.33 x 7.8 in.)
Degree of contamination 3
Degree of protection
4)
IP21
Overvoltage category III
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature -25°C to +80°C
(-13°F to 176°F)
Relative humidity maximum 85%
Maximum altitude above sea level 2000 m (6561 ft.)
Mark of conformity according to rating plate
Product standard EN62477-1
1)
The device is approved for operation on neutral-earthed networks.
2)
The thermal stress of the circuit breaker must not exceed 30,000 A
2
s.
3)
Interface to a 230/400 V and 50 Hz public grid.
4)
For indoor use only, do not expose to rain or snow.
5)
A high ambient temperature may result in power degradation (derating).
Device-specific
data
Max. AC
current
Max. AC
power
Nominal
voltage
Max.
charging
current
Weight
6)
2080 3 kW 15.1 A 3040 W 24 V 80 A 8.2 kg
(18.08 lb)
2100 3 kW 15.3 A 3290 W 24 V 100 A 8.2 kg
(18.08 lb)
2120 3 kW 15.5 A 3340 W 24 V 120 A 8.7 kg
(19.18 lb)
4045 3 kW 15.0 A 3250 W 48 V 45 A 7.4 kg
(16.31 lb)
4060 3 kW 15.2 A 3280 W 48 V 60 A 7.4 kg
(16.31 lb)
6)
With standard mains and charging leads