55
EN
NOTE!
Danger due to non-observance of the permissible mains voltage tolerance.
This can cause malfunctions and damage.
► For the electrolyte circulation option, a restricted mains voltage tolerance vis-à-vis the
charger of 207 V to 250 V applies.
The electrolyte circulation option introduces air into the battery through capillary tubes that
are provided specifically for this purpose. This allows intensive mixing of the electrolyte to
take place. The benefit is the reduced heating of the battery, and consequently longer bat-
tery-life, plus reduced water loss during charging.
If a pump fault or leaks in the connection with the battery result in a fault being detected,
then the status code "Statecode 14" will appear on the display. One way in which this fault
can be indicated is by using an external indicator lamp to show a common error.
Electrolyte circulation air filter insert
The air filter insert for the integrated air pump should be cleaned once a year. In dusty en-
vironments, the cleaning interval should be shortened accordingly. The air filter insert must
be removed for cleaning. Remove the air filter by levering it out with a slotted screwdriver;
then refit it as follows:
NOTE!
Danger from using the air filter with unsuitable chargers.
This can result in damage to property.
► Only use the air filter with the chargers provided by the manufacturer for this purpose.
Weight of the electrolyte circulation set:
Air-Puls + air hose kit
3 kW 2.5 kg (5.51 lb)