Technical data
Selectiva 8 kW
Li-Ion
Mains voltage (-10% / +10%)
1)
Optional:
3~ NPE 400 V / 50/60 Hz
3~ PE 400 V / 50/60 Hz
Mains fuse protection
2)
16 A
Minimum mains lead cross section 2.5 mm² (0.003875 in²)
Duty cycle 100%
EMC device class B
Protection class 1
Max. permitted mains impedance Z
max
on PCC
3)
None
Degree of protection
4)
IP 20
Overvoltage category III
Operating temperature
5)
-20 °C to +40 °C
(-4 °F to 104 °F)
Storage temperature -25 °C to +80 °C
(-13 °F to 176 °F)
Relative humidity maximum 85%
Maximum altitude above sea level 2000 m (6561 ft.)
Mark of conformity according to rating plate
Product standard EN62477-1
Dimensions l x w x h 633 x 180 x 344 mm
(24.92 x 7.09 x 13.54 in.)
Weight (with standard mains and charging leads) 23 kg (50.71 lb)
Pollution degree 3
1) The device is approved for operation on neutral-earthed mains networks with a
maximum outer conductor nominal voltage of 400 V.
2) If the charger is protected by a 32 A fuse, the thermal stress of the automatic circuit
breaker must not exceed 82000 A²s.
The earth leakage current is less than 3.5 mA.
3) Interface to a 230/400 V, 50 Hz public grid
4) For indoor use only, do not expose to rain or snow
5) A high ambient temperature may result in power degradation (derating).
Device-specific data
Device Max. AC cur-
rent
Max. AC power Nominal volt-
age
Max. charging
current
Selectiva 2200 11.4 A 6640 W 24 V 200 A
Selectiva 4185 15.7 A 9940 W 48 V 185 A
Selectiva 8090 14.1 A 9150 W 80 V 90 A
Selectiva 8110 15 A 9680 W 80 V 110 A