WARNING!
Danger due to unsuitable batteries being connected to the charger.
Escaping gas, fire or explosion may result in serious injury and damage to property.
Never connect a battery to the charger unless it is compatible in terms of its type, volt-
age and capacity and corresponds to the charger settings.
The charger is intended for charging lead-acid batteries and NiCd batteries. Set the charg-
er to the type of battery to be charged:
- Pb-WET batteries (PzS, GiS, ...):
Venting, closed lead-acid wet batteries with liquid electrolyte.
- Pb-GEL batteries (PzV, GiV, ...):
Valve-regulated, sealed lead-acid batteries (VRLA) with fixed electrolyte (gel or non-
woven fabric).
- NiCd batteries:
Closed or sealed NiCd batteries with liquid electrolyte.
- Pb-CSM-WET batteries (copper strained metal):
Closed lead-acid CSM batteries with liquid electrolyte.
- Lead crystal batteries:
EVFJ/CNFJ-type lead crystal batteries.
Proper handling of the device is essential for it to function correctly. Never pull on the cable
when handling the device.
Customer-specif-
ic information
If customer-specific information is available for the supplied device, supply them with the
device.
Mains connection
WARNING!
Danger due to residual current.
This can result in serious injury or death.
If required, nothing other than a type B residual current circuit breaker should ever be
used for connecting the device to the mains.
The minimum cross section of the ground conductor must conform to the local safety
requirements for electrical installations that place high demands on the ground conduc-
tor.
The device has an increased leakage current. This must be taken into account in ac-
cordance with national regulations when installing the device.
The leakage current depending on the mains voltage is indicated in the "Technical da-
ta" chapter.
WARNING!
Danger from incorrect operation.
This may result in serious injury and damage to property.
Do not use the functions described here until you have fully read and understood the
following documents:
Operating Instructions
All the Operating Instructions for the system components, especially the safety rules
Battery and vehicle manufacturer's Operating Instructions and safety rules

Table of Contents

Other manuals for Fronius Selectiva Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Selectiva Series and is the answer not in the manual?

Fronius Selectiva Series Specifications

General IconGeneral
Device CategoryBattery Charger
ManufacturerFronius
SeriesSelectiva
Microprocessor ControlledYes
Battery TypesLead-acid, AGM, Gel
Protection ClassIP20
Protection FeaturesReverse polarity, short circuit, overvoltage, overtemperature
DimensionsVaries by model