Wire-stick control
function
The wire-stick control function is available if a robot interface or field bus system is con-
nected to the LocalNet.
After the end of welding, the wire-stick control function detects any “sticking” of the wire
electrode in the solidifying weld pool. If a sticking wire electrode is detected within
750 ms after the end of welding, the error message “Err | 054” will be output.
Procedure in the event of a sticking wire electrode:
WARNING!
A welding process that starts automatically can pose a risk to life.
The “Arc on” signal must not be set while the error is being rectified, otherwise welding
will start as soon as the error is rectified.
1
Cut off the end of the wire electrode that is sticking
NOTE!
The error message “Err | 054” does not need to be acknowledged.
The power source is now ready for operation.
NOTE!
The standard factory setting is that the wire-stick control function is not activated.
If required, activate the wire-stick control function in the "Setup menu - level 2" (“Stc |
ON”).
Changing the
welding process
during CMT
Advanced weld-
ing
NOTE!
Neither the welding process nor the currently selected characteristic can be
changed during CMT Advanced welding.
To change the welding process or characteristic:
1
first, end the CMT Advanced process
2
wait 300 - 600 ms
Another welding process or characteristic can be selected during this time.
3
Resume the welding process with another welding process or characteristic
115
EN
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044