EasyManuals Logo

Fronius TransPuls Synergic 5000 User Manual

Fronius TransPuls Synergic 5000
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
Wire-stick control
function
The wire-stick control function is available if a robot interface or field bus system is con-
nected to the LocalNet.
After the end of welding, the wire-stick control function detects any “sticking” of the wire
electrode in the solidifying weld pool. If a sticking wire electrode is detected within
750 ms after the end of welding, the error message “Err | 054” will be output.
Procedure in the event of a sticking wire electrode:
WARNING!
A welding process that starts automatically can pose a risk to life.
The “Arc on” signal must not be set while the error is being rectified, otherwise welding
will start as soon as the error is rectified.
1
Cut off the end of the wire electrode that is sticking
NOTE!
The error message “Err | 054” does not need to be acknowledged.
The power source is now ready for operation.
NOTE!
The standard factory setting is that the wire-stick control function is not activated.
If required, activate the wire-stick control function in the "Setup menu - level 2" (“Stc |
ON”).
Changing the
welding process
during CMT
Advanced weld-
ing
NOTE!
Neither the welding process nor the currently selected characteristic can be
changed during CMT Advanced welding.
To change the welding process or characteristic:
1
first, end the CMT Advanced process
2
wait 300 - 600 ms
Another welding process or characteristic can be selected during this time.
3
Resume the welding process with another welding process or characteristic
115
EN
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals