tS2 | xxx
Note: xxx is a temperature value
Overtemperature in the secondary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
tS3 | xxx
Note: xxx is a temperature value
Overtemperature in the secondary circuit of the power source
Allow power source to cool down
Cause:
Remedy:
Power source -
troubleshooting
tSt | xxx
Note: xxx is a temperature value
Overtemperature in the control circuit
Allow power source to cool down
Cause:
Remedy:
Power source does not function
Mains switch is on, but indicators are not lit up
There is a break in the mains lead; the mains plug is not plugged in
Check the mains lead, ensure that the mains plug is plugged in
Mains socket or mains plug faulty
Replace faulty parts
Mains fuse protection
Change the mains fuse protection
Short circuit on the 24 V supply of SpeedNet connection socket or external
sensor
Unplug connected components
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
183
EN
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals