Irregular wire feed speed
Braking force has been set too high
Loosen the brake
Hole in the contact tip is too narrow
Use a suitable contact tip
Faulty inner liner in welding torch
Check the inner liner for kinks, dirt, etc. and replace if necessary
The feed rollers are not suitable for the wire electrode being used
Use suitable feed rollers
Feed rollers have the wrong contact pressure
Optimise the contact pressure
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Wirefeed problems
when using long hosepacks
Incorrect arrangement of hosepack
Arrange the hosepack in as straight a line as possible, avoid tight bends
Cause:
Remedy:
Welding torch becomes very hot
The specification of the welding torch is inadequate
Observe the duty cycle and loading limits
Only on water-cooled systems: Inadequate coolant flow
Check coolant level, coolant flow, for coolant contamination, etc. For further
information refer to the cooling unit operating instructions.
Cause:
Remedy:
Cause:
Remedy:
186
Toowoomba Welding Supplies : tweld.com.au : Ph +61 7 4659 0044

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals