60
20. All FMU’s prompted, “PUMP CURRENTLY IN USE, SELECT ANOTHER…” when a
dispenser in use was selected from the FMU keypad. Should also display an asterisk (*) to
the left of the hose number when selecting the hose. Asterisk indicates hose is in use.
21. All FMU’s successfully activate appropriate dispenser hoses after reading an authorized
Prokee
®,
Smartcard, or credit card. When appropriate responses are given to prompts on
FMU display, selected hose was activated for fueling. Run a test transaction on each
hose. Record the hose number and quantity.
22. Accurate transaction data was received by Central Controller after polling master FMU.
Compare the transaction data accumulated in step 21, above, with transaction data
downloaded to the Central Controller. Hose numbers and quantities must match.
23. Each FMU allowed simultaneous operation of all connected dispenser hoses, and all FMU’s
operated simultaneously. It should be possible to activate every hose connected to each
FMU, and it should be possible to activate all the FMUs at the same time.
24. Activate each hose (one hose at a time) in automatic mode and verify no other hoses will
dispense at the same time without being activated. This is a test to ensure each hose is
individually controlled, with no jumpers tying two hoses together.
25. Perform the Switch Test for manual mode. Verify hoses switched to auto display a “0” under
the hose number, and hoses switched to manual display a “1” under the hose number. Verify
hoses switched to manual do not appear on the FMU display as being available for an
automated transaction. Verification that the system is correctly recognizing position of
auto/manual switches, and hoses are wired into the correct positions of the Pedestal
I/O Board.
26. If a receipt printer is in use, verify that the receipt prints and is correct. Verification that the
receipt is accurate and provided for the fueling customer.
27. If FMU is using credit cards, run a transaction on each hose to verify pricing and functionality.
Verification of correct setup of credit card functions, and accuracy of pricing.
28. If customer is using a Keyless system type, verify the FMU Keyless configuration has been
set to match customer’s desired options, and the default screen prompts have been changed
accordingly. When the Keyless option is enabled, FMU display prompts should remove
any requests to insert key or card.
29. If customer uses proximity cards and/or AIM2™ user IDs, ensure proper operation of both
functions, and screen prompts reflect the selected options. FMU should display prompt for
entry of User ID/swipe proximity card if user ID option is turned on. Transaction should
cancel if an authorized User ID or proximity card is not detected.
SECTION II. Complete when performing startups for new AIM2™ sites. This includes sites
upgraded for AIM2™ operation. The following checks are unique to AIM2™, and in addition to the checks
required to be performed following the completion of an FMU installation.
AIM2™ SOFTWARE OPERATIONS
1. AIM2™ was enabled in the software system configuration. “Configuration” window should
reflect AIM2 “Passive Sys Type”.
2. FMU type in the site configuration was configured for AIM2™ or AIM2™ programmer. “Site
ID XXXX” window should reflect “FMU:” as “FMU 2500 Plus AIM II” or “FMU 2500 Plus
AIM II Prog”.