48
******AIM PROGRAMMING COMPLETE*******
changing to:
NOTE
Some older versions of FMU firmware may show RESET instead of CLEAN in the following
display.
VID: 1001555 [-MAIN MENU-] (PHT A)
1=CALIBRATE 2=INTERFACE 3=CLEAN D=EXIT
NOTE
The message No Record Found indicates no AIM2™ vehicle record has been found for the VID
entered. Ensure the correct vehicle ID was entered, and the AIM2™ vehicle record has been sent to
the FMU. In the Central Controller, the vehicle record should display AIM Program Pending. If an
error was found, respond to the following question by depressing the Yes key, and try again.
VID: 1001555 (PHT A)
NO RECORD FOUND. TRY AGAIN (Y/N)?
9. Depress D=EXIT until the FMU returns to the default display. Insert an AIM2™ Installation
Notice in the vehicle to inform users of the AIM2™ installation. If calibration, change
interface, or clean is desired, continue to one of the following actions.
Calibrate AIM2™: calibration may be used to recalibrate odometer or chronometer settings, a
useful option when transferring AIM2™ modules to a new vehicle. Odometer will appear under the
CALIBRATE choices, regardless of OBD or analog interface, or regardless of any chronometer
selection. If no chronometers were selected when building the vehicle record, odometer recalibration
will be the only option. If chronometers were selected when building the vehicle record, the recalibrate
options will include odometer plus the selected chronometers. Access to the [-MAIN MENU-] is only
possible by first reprogramming the AIM2™ module.
NOTE
AIM2™ programming may be initiated with a Supervisor Prokee®/Smartcard or an AIM2™
Programmer Prokee®/Smartcard. The following instructions begin using a Supervisor
Prokee®/Smartcard. Procedures when using an AIM2™ Programmer Prokee®/Smartcard begin with
the display shown in step 3.
1. Insert a Supervisor Prokee®/Smartcard. The following will be displayed:
* SUPV: 1=SYSTEM, 2=PM, 3=ODOM, 4=AIM *
* A=CONFIG, B=ISSUES, C=TANKS, D=EXIT *
2. Depress 4=AIM. The following will be displayed:
NOTE
Some older versions of FMU firmware may show RESET instead of CLEAN in the following
display.
AIM SUPERVISOR MENU
1=SET PHT, 2=PROGRAM, 3=CLEAN, D=EXIT