3.1.5 Fast Recovery
This function recovers data quickly by relocating data in the failed drive to the other remaining drives when a
drive error is detected.
A RAID level (RAID6-FR) that preserves reserved areas equivalent to hot spares in a RAID group is used.
Figure 3.5 Fast Recovery
3.1.6 Protection (Shield)
The Protection (Shield) function diagnoses temporary drive errors. A drive can continue to be used if it is de-
termined to be normal. The target drive temporarily changes to diagnosis status when drive errors are detec-
ted by the Disk Drive Patrol function or error notifications.
For a drive that configures a RAID group, data is moved to a hot spare by a rebuild or redundant copy before
the drive is diagnosed.
For a drive that is disconnected from a RAID group, whether the drive has a permanent error or a temporary
error is determined. The drive can be used again if it is determined that the drive has only a temporary error.
The target drives for the Protection (Shield) function are all the drives that are registered in RAID groups or
registered as hot spares. Note that the Protection (Shield) function is not available for unused drives.