Exchanging the heat sink Processors
6.3 Exchanging the heat sink
Ê Open the server as described in the chapter “Preparation” on page 17f.
Ê Remove the air duct.
Ê Remove the four screws of the heat sink in diagonally opposite sequence
(see page 29).
Ê Turn the heat sink carefully back and forth to loosen it. Then lift it out to
remove it.
Ê Clean the surface of the processor with a lint-free cloth.
Ê Fit the heat sink on the processor such that airflow arrow is facing to the rear
side of the server (see page 28).
Ê Attach the heat sink with four screws. Tighten the screws in diagonally
opposite sequence (see page 28).
Ê Reinstall the air duct. Ensure that the hooks on the air duct (see figure 8 on
page 24) engage on the fan’s rear panel.
Ê Close the server, plug in the power plugs, and switch on the server as
described in the chapter “Completion” on page 41f.