102 Operating manual RX200 S4
Replacement of non-hot-plug components CSS components
8.2 Replacement of non-hot-plug components
When a defective non-hot-plug component has been detected (for more infor-
mation see chapter ā€œStartup and operationā€ on page 57 and the "Customer Self
Service (CSS)" manual on the ServerBooks DVD), proceed as follows:
Ê Exit all applications and shut down the server properly (see section
ā€œSwitching the server on and offā€ on page 67).
Ê Pull all power plugs out of the insulated sockets of the rack's internal power
supply.
Ê Remove the server from the rack (see section ā€œInstalling/removing the server
in/from the rackā€ on page 41) and put the server on a table, for example.
8.2.1 Opening the server
Figure 31: Removing the housing cover
Ê Unlock the housing cover by pressing the housing button (1).
Ê Push the housing cover as far as it will go in the direction of the arrow (2).
Ê Lift off the housing cover upwards.