46 Operating manual RX200 S4
Installing/removing the server in/from the rack Hardware installation
4.2.1 Installation in PRIMECENTER/DataCenter Rack
For installation in a PRIMECENTER/DataCenter Rack, the following parts are
required:
ā Support bracket
ā One left and one right telescopic rail (assembled)
ā M5x10 screws with integrated plugwashers
I ā Or, M5x10 screws with separate plugwashers can also be used. In
this case, two plugwashers each must be fitted beforehand on the
support uprights and the support bracket.
ā The descriptions and figures in this section refer to the current
variable support.
ā General information is provided in the Technical Manual for the
PRIMECENTER and/or DataCenter Rack.
When mounting the left telescopic rail in the PRIMECENTER/DataCenter Rack,
the supplied support bracket must first be mounted on the rear left support
upright flush with the bottom edge of the device.