TX200 S6 Options Guide 39
Main memory
Memory modules of different capacities may be mixed on a bank by bank
basis (2x2) in the Mirrored Channel Mode and in the Spare Channel Mode.
The assignment of DIMM slots to the memory banks and channels is
imprinted on the system board.
Install memory modules within a channel in descending order of capacity:
higher capacity in the black slot; lower capacity in the blue slot.
5.2 Expanding the main memory
Ê Open the server and remove system fan 2 (or 2&4) as described in the
chapter "Preparation" on page 27.
Ê Press the securing clips on both sides of the memory slot concerned
outward.
Figure 11: Expanding the memory module
Ê Carefully press the memory module into the slot (1) until the securing clips
on both sides of it engage (2).
Ê Reinstall system fan 2 (or 2&4) as described in the section "Installing system
fan 2 (or 2&4)" on page 108.
Ê Close the server, connect it to the power outlet, and switch it on as described
in the chapter "Completion" on page 107.