160
Model Menu (Airplane/Glider)
ڀ ŪŲŃƗƒŃŷŤťůŨŃŲũŃŦŲűŷŨűŷŶ
$,53/$1(
*/,'(5
ŏ5HWXUQWR0RGHO0HQX
*\UR
>&RUUHVSRQGLQJPRGHOW\SH@$LUSODQHJOLGHUJHQHUDO
This function is used when a gyro is used to
VWDELOL]HWKHIXVHODJHDWWLWXGH7KHVHQVLWLYLW\DQG
RSHUDWLRQPRGH1RUPDOPRGH*<PRGHFDQEH
switched with a switch.
ŏ7KUHHUDWHV5DWH5DWH5DWHFDQEHVZLWFKHG
ŏ8SWRWKUHHD[HV*\UR*\UR*\URFDQEH
simultaneously controlled.
ŏ7RXFKWKH>*\UR@EXWWRQLQWKH0RGHO0HQXWR
FDOOWKHVHWXSVFUHHQVKRZQEHORZ
,QLWLDOVHWWLQJGRHVQRWDVVLJQDVHQVLWLYLW\FKDQQHO8VHWKH
Function menu of the Linkage Menu to assign the sensitivity
FKDQQHO*\UR*\UR*\URXVHGWRDYDFDQWFKDQQHO
beforehand.
6HW>$&7@DQG>7ULP@RWKHUWKDQ)XQFWLRQWR>18//@
ŏ7KHRSHUDWLRQPRGH$9&6125DQGVHQVLWLYLW\RIWKH
D[HV*\UR*\UR*\URFDQEHVHW
ŏ*URXSVLQJOHPRGHVZLWFKLQJ*U
6QJO
(For more information, see the
GHVFULSWLRQDWWKHEDFNRIWKLVPDQXDO
ŏ7KUHHUDWHV5DWH5DWH5DWHFDQEHXVHG
ŏ7RXFKWKH$&7EXWWRQRIWKHUDWHWREHXVHGDQGVHWWKHIXQFWLRQWR$&7>21@RU>2))@
ŏ:KHQD)XWDEDJ\URLVXVHGZKHQ>*<@W\SHLVVHOHFWHGWKHVHQVLWLYLW\VHWYDOXHLVGLUHFWO\
UHDGLQERWKWKH$9&6DQG125PRGHV
ŏ:KHQVHWWLQJDVZLWFKWRXFKWKHVZLWFKEXWWRQWRFDOOWKH6ZLWFK!VFUHHQDQGWKHQ
VHOHFWWKHVZLWFKDQGVHWLWV21GLUHFWLRQ
([DPSOH6HWWLQJWKUHHD[LVXVLQJD*<$DQG*<$
ŏ:LQJW\SH$LOHURQVHUYRVPRXQWHGIXVHODJHVHOHFWHG
ŏ6HW
5CH GYRO
*<$$,/
7CH GYRO2
*<$(/(
8CH GYRO3
*<$58'
ControlandTrim NULL
DWWKH
)XQFWLRQPHQXRIWKH/LQNDJHPHQX
ŏ*<52VHWWLQJRIWKH0RGHOPHQX
*Set so that Rate1 is turned on at the back position of switch E and
5DWHLVWXUQHG21DWWKHIURQWSRVLWLRQ6LQFHVZLWFK(LVWXUQHG
2))DWWKHFHQWHU5DWHUHPDLQV>,1+@
Rudderservo
Elevatorservo
Aileronservo
S.BUS2port
S.BUSReceiver
GYA451
GYA451
GYA450
GAIN0%
AVCS
NORMAL
WhenAVCSisusedwe
recommendthatthe
sensitivityCHbesetto
the3-position.
Rate ACT Type Switch GYRO GYRO2 GYRO3
1 OFF/ON GY SE AVCS:60% AVCS:60% AVCS:60%
2INH
3 ON/OFF GY SE NORM:60% NORM:60% NORM:60%