FlightTune(Aileron/ElevatorBasicsettings)
FlightTune(Aileron/ElevatorBasicsettings)
(3) Cnt. AuthAIL: Control Authority Aileron
AileronControlAuthoritychangestherateatwhich thegyrowilltryto
achievetheset"CYC.Rt".Ahighervaluewillcreateaquickeraccelerated
reactiontoastickinputtoreachandstabilizetothe"CYC.Rt"value;a
lowervaluewillreachthedesired"CYC.Rt"slowerandaccelerateslower
tothedesiredangularrate.
Note:Settingthisvaluetoohighcouldleadtoajerkyfeelingwhenmak
-
ingrapidstickcorrections,avaluetoolowwillgiveyou theimpression
themodelisnotfollowingthepilotʼ sstickinputs.Valuesofbetween
20-60arethesuggestedrangeformosthelicopters.
Settingranges:0~100%
Initialvalue:Cnt.AuthAIL=40%
(4) Cnt. AuthELE: Control Authority Elevator
ElevatorControlAuthoritychangestherateatwhichthegyrowilltryto
achievetheset"CYC.Rt".Ahighervaluewillcreateaquickeraccelerated
reactiontoastickinputtoreachandstabilizeatthe"CYC.Rt"value;a
lowervaluewillreachthedesired"CYC.Rt"slowerandaccelerateslower
tothedesiredangularrate.
Note:Settingthisvaluetoohighcouldleadtoajerkyfeelingwhenmak
-
ingrapidstickcorrections,avaluetoolowwillgiveyou theimpression
themodelisnotfollowingthepilotʼ sstickinputs.Valuesofbetween
20-60arethesuggestedrangeformosthelicopters.
Settingranges:0~100%
Initialvalue:Cnt.AuthELE=40%
(5) EXPO.: Exponential
Tunetheexponentialasdesiredtochangethefeelofthecycliccontrols
aroundcenterstick.Negativevaluessoftencontrolfeel; Positivevalues
increasesensitivity.
Note:thatanyexponentialpresentintheTRANSMITTERaddstothe
valuesetintheCGY.
Settingranges:-100~0~+100%Initialvalue:-20%
(6) FLT. Styl: Flight style
Increasingthisvaluewillcreateamoreroboticreactiontothestick,leav-
ingthepilotwiththeimpressionthatthemodelislockedintoinaposition
afteraninput.Itwillalsotendtohaveamorecalculatedfeelingwhen
makinginputs.
-Loweringthevaluewillmakethemodelfeelmorefluidandeasytorotate
withthestickinput.Themodelwillfeelalittlemorelivelyduringfastercy
-
clicmovementsanddirectionchanges.
Settingranges:0~+100
nInitialvalue:+50