170 ● NB DMC-40x0 Command Reference
NB
FUNCTION: Notch Bandwidth
DESCRIPTION:
The NB command sets real part of the notch poles
ARGUMENTS: NB n,n,n,n,n,n,n,n or NBA=n where
n is ranges from 0 Hz to
1
16()⋅ TM
USAGE: DEFAULTS:
While Moving Yes Default Value 0.5
In a Program Yes Default Format 3.1
Command Line Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_NBn contains the value of the notch bandwidth for the specified axis.
RELATED COMMANDS:
NF Notch Filter
NZ Notch Zeros
EXAMPLES:
_NBA = 10 Sets the real part of the notch pole to 10/2 Hz
notch = _NBA Sets the variable "notch" equal to the notch bandwidth
value for the A axis
Note: TM in seconds and defaults to .001