3E1151SmartScale800UserManual
28
Options Description
thereisaslightdecreaseintheaccuracyofweight
measurements.
SorterSpecial2 Enablestheconnectionoflatermodelautosorters
(suchasthePrattleyautosorter)thatcommunicate
backtotheScaleusingdefinedprotocols.
SorterSpecial3 SameasSorterSpecial2butwithafasterweight
lockingtimeaspertheSorterFast.
Ruddweigh Enablestheconnectionofdevicesusingthe
Ruddweighprotocol.Notavailableinsomecountries.
(NZ/AUonly)
3. Press tosavethesettingsandreturntotheSetupmenu.
Autosorter
TheScalecaninterfacedirectlywithautosorters.Therearefouroptionsfor
communicatingwiththeconnectedport,Sorter,SorterSpecial,SorterSpecial2
andSorterFast.
TheScalesendssortingcommandstotheautosorterduringtheweighingsession.
ToconnectanautosorterwiththeScale,completethefollowingsteps:
1. TurnontheScale.
2. Ensuretheautosorteristurnedoff.
3. ConnecttheautosortertooneoftheportsontheScale.
4. Settheporttotherequiredoption,Sorter,SorterSpecial,SorterSpecial2or
SorterFast.SeeCommunications(p26)formoreinformation.
5. Turntheautosorter
on.
Note:Forinformationaboutsettinguptheautosorterintothree‐waysorting,seeSort
menu(p12).
PowerfeedtoElectronicIDreaders
TheScalecansupplypowertoanElectronicIDreader.Powerissuppliedonlyif
thereaderisconnectedtoPort2andifanyoneofthethreeElectronicIDreader
optionsisselected.
WithPort2,ifyounominateadeviceotherthananElectronicIDreader,power
feed
isdisabled.IftheElectronicIDReaderyouareusingdoesnotrequirepower
fromtheScale,youcanconnectittoeitherPort1orPort2.