Configuration
22 · G&D DVIVision
Authorising permanent activation of input lock
If no inputs are being made at the active console during the adjusted timeout of the
automatic input lock (default: 1
second), the default settings of the DVIVision
system also permit to operate the system from the other console.
If the function Authorising permanent activation of input lock is activated in the setup
menu, the users of the DVIVision system are enabled to permanently activate the
input lock with the key combination Hotkey
+ Print Screen (default:
Ctrl
+ Print Screen).
After having pressed this key combination, the input devices of the concurrent con-
sole are deactivated. By pressing the key combination again at the active console,
both consoles are again able to operate the DVIVision system after the automatic
input lock has elapsed.
When the permanent input lock has been activated at one console, the Scroll LEDs
are blinking on the keyboards of both users.
How to (de)activate the Authorising permanent activation of input lock function:
Related topics:
Timeout of the automatic input lock on page 21
Changing the videomode of the user consoles on page 23
This function can only be (de)activated in the setup menu.
setup menu
1. Establish the connection to the DVIVision system through the terminal
emulation program.
2. Select the row Permanent Access CPU with the arrow keys, if you want to
change this setting for the local console.
Select the row Permanent Access CON with the arrow keys, if you want to
change this setting for the remote console.
3. Press the Space key (repeatedly) to (de)activate this function:
Yes activation of the permanent input lock possible
No activation of the permanent input lock not possible
4. After having selected the desired setting, press the S key to save the settings.