Programming Sens / Xp / Custom
Up to 8 custom output may be programmed. (Model dependant).
A custom output may be used so that the output can follow a zone or a user code.
1) Enter into Engineer Mode
To do this follow Steps 1 to 4 on page 79
With the display showing:-
2) Press No eleven times. The display will show:-
3) Press Yes. The display will show:-
4) Press No. The display will show:-
Choose from one of the options displayed. E.g. If 9
is selected Latch will operate when ANY detector
is triggered.
5) The display will show:-
6) Press No until the required setting is displayed,
then press Yes. The display will show:-
With the Latch programmed as Latch Any, the output will switch high when this is set
as +V. With this set as -V the output will be inverted.
7) Press No until the required setting is displayed
then press Yes. The display will show:-
Program . . . . _ _ _
Zones ?
Program . . . . _ _ _
Sens / Xp / Custom ?
Latch O/P
= Latch Any =+V
Latch O/P
>Latch Any =+V
Choose . . 1 - 7 = Area
8 = All 9 = Any
Latch O/P
=Latch Any >+V
Sensor O/P . .
=Pulse Off =+V
PR5892 Rev11 800 Series Eng Ref 15.qxd 16/11/2006 11:21 Page 135