Page 23
ACE Receiver Wiring & Jumper Options
ACE is also available as a stand alone receiver. The wiring for the receiver is the same
as for the RKP(s) with the exception that the speaker wiring terminal on the ACE is
marked as SP- and not SPKR.
The ACE receiver is link selectable as unit No.1 or unit No.2 and it is permissible to
have two units sharing the same ident.
Five options are available that are selected with jumper links.These options are as
follows.
(US) (Not present on keypads from 2004)
This jumper is the user select. With the jumper link removed each ACE key fob will
occupy one user code from the system, this is termed as high security mode.
With the jumper link in position the ACE will occupy one user code from the system but
up to fourteen key fobs may be programmed into the ACE, this is normal security
mode.
JP2 (RP)
This jumper is only used when the ACE is fitted to the Gardtec 800 Series control
panels and is used to select the ACE ident as 1 or 2 . This ident should be viewed as
the RKP ident. With the jumper off the ACE will be remote device two, with the jumper
fitted the ACE will be device number one.
JP4 (RST)
The ACE has a Non-Volatile Memory (NVM). If power is applied to the unit with this
jumper in position, the memory contents will be erased. When the unit is first powered
up, this jumper should be in position for at least 5 seconds. After this initial period the
jumper link should be removed.
If a reset of the ACE is required (all fobs to be deleted) this jumper link should be
refitted and the unit re-powered.
Note: Ensure all links are in desired position before powering up the ACE.
PR5892 Rev11 800 Series Eng Ref 15.qxd 16/11/2006 11:20 Page 23