Note: some of these jumpers may not be fitted on versions without ACE
(ACE User Select) ACE units only
This jumper is the user select. With the jumper link removed each ACE key fob will
occupy one user code from the system, this is termed as high security mode.
With the jumper link in position the ACE will occupy one user code from the system but
up to fourteen key fobs may be programmed into the ACE, this is normal security
mode.
(Reset) ACE units only
The ACE has a Non-Volatile Memory (NVM). If power is applied to the unit with this
jumper in position, the memory contents will be erased. When the unit is first powered
up, this jumper should be in position for at least 5 seconds. After this initial period the
jumper link should be removed.
If a reset of the ACE is required (all fobs to be deleted) this jumper link should be
refitted and the unit re-powered.
Note: Instructions for how to program keyfobs to the ACE and using ACE are
contained within the user manual