Page 69
Reset of the factory defaults and entering Engineer Mode:-
Note: It is
ESSENTIAL
that a 4 6 Yes No reset is done to all new systems
before commencement of programming.
1) Remove all power from the system for at least ten seconds
2) Apply mains power to the control panel.
The display will show, for example:-
(Display will differ dependant on panel version)
3) Whilst this display is showing (the first five
seconds) press the keys shown in a, b or c
for the reset required. (E.g. 4 6 Yes No).
The display will show:-
This may show for several minutes.
4) The display will then show:-
Selecting 1:BS - Panel may be programmed to comply with the old BS4737 Standards. DD243
requirements will still apply.
Selecting 2:EN2 - Panel may be programmed to comply with EN50131-1 for Grade 2 Systems.
DD243 requirements will still apply.
Selecting 3:EN3 - Panel may be programmed to comply with EN50131-1 for Grade 3 Systems.
DD243 requirements will still apply
5) Select 2:EN2.The display will then show:-
This may show for several minutes.
The display will then show:-
6) Enter Engineer code.
(1234 default EN2). The display will show:-
Note: User Codes and Engineer Codes MUST be six digits in
length for EN3 installations.
7) Enter the Authorisor code. The Authorisor code is
the Master User, (default 5678 EN2).
The display will show:-
Note: It may be required that an engineer has to be authorised by a user before access to the
Engineer mode is granted.
8) Press Yes. The display will show:-
Gardtec872 xx-xx
Please Wait
Select Standard
1:BS 2:EN2 3:EN3
Enter Authorisor
Code . . . . . .
Please Wait
Do you want to . .
Use ENGNR. Mode ?
Program Zones . . . . - - -
Zones ?
01 Jan 00:01:50
PR5892 Rev11 800 Series Eng Ref 15.qxd 16/11/2006 11:20 Page 69