Fig. 24 Typical 2 Wire EOL Configuration
+ -
12V
+ -
AZ1
+ -
TZ1
+ -
AZ2
+ -
TZ2
+ -
AZ3
+ -
TZ3
+ -
AZ4
+ -
TZ4
+ -
AZ5
+ -
TZ5
+ -
AZ6
+ -
TZ6
+ -
AZ7
+ -
TZ7
+ -
AZ8
+ -
TZ8
ALARM
ZONE 1
+ LOOP
ALARM
ZONE 9
- LOOP
ALARM
ZONE 2
+ LOOP
ALARM
ZONE 10
- LOOP
ALARM
ZONE 3
+ LOOP
ALARM
ZONE 11
- LOOP
ALARM
ZONE 4
+ LOOP
ALARM
ZONE 12
- LOOP
ALARM
ZONE 5
+ LOOP
ALARM
ZONE 13
- LOOP
ALARM
ZONE 6
+ LOOP
ALARM
ZONE 14
- LOOP
ALARM
ZONE 7
+ LOOP
ALARM
ZONE 15
- LOOP
ALARM
ZONE 8
+ LOOP
ALARM
ZONE 16
- LOOP
DETECTOR
SUPPLY
Single Passive Infra-Red
Normally Closed Alarm Pair
Normally Closed Alarm Pair
+ Supply
- Supply
Single Contact
Exit Terminator Button
(if required)
Normally Open Push Button
Normally Open Pressure Pad
(To Detector Supply -ve)
Single Pressure Pad
(Pressure Pads on AZ Zones
Only)
To detector -ve supply
Note:
If exit terminator is required program zone as ET
If unset doorbell is required allocate chime to the
ET zone.
Exit terminator zone must be AZ zone
Setting Mode should be programmed for ET
Note:
Maximum of 10 detectors per loop using EOL
Note:
Resistor Colour Codes Are:-
4K7 = Yellow, Purple, Red
6K8 = Blue, Grey, Red
Note:
All unused zones should have factory fitted link removed
and replaced with the 4K7 EOL Resistor.
It is not advisable to fit normally open devices
onto TZ loops.
All Normally Closed Contacts
Multiple Contacts
4K7
4K7
6K8
27K
6K8
6K8
4K7
4K7
27K
4K7
27K = Red, Violet, Orange