DET-653C EntelliGuard
®
G Circuit Breaker Application Guide
24-May-12 Section 5. Catalog Numbering Guide
©2012 General Electric All Rights Reserved
Digit 12 – Auxiliary Switch
Auxiliary Switch, 3NO+3NC (Power Rated)* STANDARD/INCLUDED
Auxiliary Switch, 8NO+8NC (Power Rated)***
Aux. Switch, 3NO/3NC (Power Rated) + 2NO/2NC low signal (Hi-Fi)
Aux. Switch, 4NO/4NC (Power Rated) + 4NO/4NC low signal (Hi-Fi)***
Auxiliary Switch, 3NO+3NC
(Power Rated)
CSC, PR, (1 NO on SD) - Close Coil or CCC
CSC, Hi-Fi via Trip Unit - Close Coil or CCC**
CSC, PR, (1 NO on SD) - 1st Shunt Trip
CSC, Hi-Fi via Trip Unit - 1st Shunt Trip **
CSC, PR, (1 NO on SD) - 1st UVR
CSC, Hi-Fi via Trip Unit - 1st UVR**
CSC, PR, (1 NO on SD) - 2nd ST or 2nd UVR
CSC, Hi-Fi via Trip Unit - 2nd ST or 2nd UVR**
Aux. Switch, 3NO/3NC (PR) + 2NO/2NC
Low Signal (Hi-Fi)
CSC, PR, (1 NO on SD) - Close Coil or CCC
CSC, Hi-Fi via Trip Unit - Close Coil or CCC**
CSC, PR, (1 NO on SD) - 1st Shunt Trip
CSC, Hi-Fi via Trip Unit - 1st Shunt Trip**
CSC, PR, (1 NO on SD) - 1st UVR
CSC, Hi-Fi via Trip Unit - 1st UVR**
CSC, PR, (1 NO on SD) - 2nd ST or 2nd UVR
CSC, Hi-Fi via Trip Unit - 2nd ST or 2nd UVR**
Auxiliary Switch, 3NO+3NC
CSC, PR, (1 NO on SD) - All Installed Devices
CSC, Hi-Fi via Trip Unit - All Installed Devices**
Aux. Switch, 3NO/3NC (PR) + 2NO/2NC
Low Signal (Hi-Fi)
CSC, PR, (1 NO on SD) - All Installed Devices
CSC, Hi-Fi via Trip Unit - All Installed Devices**
= Command Operated Close Coil
= Coil Signaling Contact
= High Fidelity
= Power Rated
= Secondary Disconnect
*The 3NO/3NC scheme is STANDARD (INCLUDED, CODE 2) and is wired to Secondary Disconnect Block A, all other selections require Secondary Disconnect
Block B.
**In order to output the Coil Signaling status Hi-Fi via trip unit (options B, D, F, H, K, M, P,R, T, and V) a communications package must be selected in Advanced
Features (Digit 19; options 2, 3, 6, 7, 8, 9). This option requires Secondary Disconnect Block B.
**If a UL or ANSI Switch is selected in Digit 2 (C, D, M, S), the Hi-Fi via Trip Unit options are not valid (options B, D, F, H, K, M, P, R, T, V).
***For Side-mounted Secondary Disconnect Blocks, all options are available EXCEPT options 4 and 8.
• The term “Hi-Fi” refers to gold-plated contacts used for signal level outputs (10mA minimum - 100mA maximum, 5-30Vdc, 125Vac).
• If no devices were selected in Digit 8, 9, 10, 11 (Codes = "X"), then Options A - V are invalid.
• Options A-V are only valid if the corresponding device to be monitored by the Coil Signaling Contact (CSC) is selected in digits 8, 9, 10, 11.