G Circuit Breaker Application Guide
24-May-12 Section 5. Catalog Numbering Guide
©2012 General Electric All Rights Reserved
Digits 6 & 7 – Overcurrent Protection Package (for EntelliGuard
®
G Breakers)
Over Current (OC) Protection Package
EntelliGuard G
ANSI/UL OC Protection
with Fuse Settings
Standard Range
Instantaneous
LSI (S, switchable) (I, switchable ANSI only)
LSIG (S, switchable) (I, switchable ANSI only)
LSIGA (S, switchable) (I, switchable ANSI only) (G, alarm only)
LSIC (S, switchable) (I, switchable ANSI only)
LSICA (S, switchable) (I, switchable ANSI only) (C, alarm only)
LSIGDA* (S, G, A switchable) (I, switchable ANSI only)
LSIGCDA* (S, G, C, A all switchable) (I, switchable ANSI only)
Extended Range
Adjustable
Instantaneous
LSH (S, switchable) (I, switchable ANSI only)
LSHG (S, switchable) (I, switchable ANSI only)
LSHGA (S, switchable) (I, switchable ANSI only) (G, alarm only)
LSHC (S, switchable) (I, switchable ANSI only)
LSHCA (S, switchable) (I, switchable ANSI only) (C, alarm only)
LSHGDA* (S, G, A switchable) (I, switchable ANSI only)
LSHGCDA* (S, G, C, A all switchable) (I, switchable ANSI only)
EntelliGuard G
ANSI/UL OC Protection
with Fuse Settings
FROM 1/1/12:
INCLUDED IN L TYPE
TRIP UNITS
Standard Range
Instantaneous
JSI (S, switchable) (I, switchable ANSI only)
JSIG (S, switchable) (I, switchable ANSI only)
JSIGA (S, switchable) (I, switchable ANSI only) (G, Alarm Only)
JSIC (S, switchable) (I, switchable ANSI only)
JSICA (S, switchable) (I, switchable ANSI only) (C, Alarm Only)
JSIGDA* (S, G, A all switchable) (I, switchable ANSI only)
JSIGCDA* (S, G, C, A all switchable) (I, switchable ANSI only)
Extended Range
Adjustable
Instantaneous
JSH (S, switchable) (H, switchable ANSI only)
JSHG (S, switchable) (H, switchable ANSI only)
JSHGA (S, switchable) (H, switchable ANSI only) (G, Alarm Only)
JSHC (S, switchable) (H, switchable ANSI only)
JSHCA (S, switchable) (H, switchable ANSI only) (C, Alarm Only)
JSHGDA* (S, G, A all switchable) (H, switchable ANSI only)
JSHGCDA* (S, G, C, A all switchable) (H, switchable ANSI only)
= Ground Fault, External Ground Fault, Alarm only.
= External CT for ground fault detection (AKD20 application: input from external summing CTs, used for multiple source ground fault detection. OEM
Application: Zero Sequence Input of 1A = 100%).
= Defeatable/Switchable Ground Fault NOT UL Listed.
= Ground Fault Protection (GFP, 3-wire or 4-wire, internal summing).
= Extended Range Adjustable Instantaneous, (IOC, 2x-30x), Only for ANSI EntelliGuard G.
= Standard Range Adjustable Instantaneous, (IOC, 2x-15x).
= Long Time (L, I
2
t) + Fuse Settings (I
4
t).
= Long Time (I
2
t, all trip unit).
= Short Time (Switchable if Instantaneous (I) protection is enabled).
= Ground Fault Alarm only.
= External Ground Fault Alarm only.
= Ground Fault Trip and Ground Fault Alarm (all switchable, Not UL Listed).
* Function combination is NOT UL Listed.