ADV200 • Functions description and parameters list 195
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4538 KTY84/PTC current mA UINT32 2 1 10 ERWS
Value of current owing in connected temperature sensor KTY84.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4708 Alm dig out mon 1 BIT 16 0 0 1 ER
This signal is activated when the alarm congured in parameter 4700 alarm dig sel 1 is active.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4710 Alm dig out mon 2 BIT 16 0 0 1 ER
This signal is activated when the alarm congured in parameter 4702 alarm dig sel 2 is active.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4712 Alm dig out mon 3 BIT 16 0 0 1 ER
This signal is activated when the alarm congured in parameter 4704 alarm dig sel 3 is active.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4714 Alm dig out mon 4 BIT 16 0 0 1 ER
This signal is activated when the alarm congured in parameter 4706 alarm dig sel 4 is active.
Menu PAR Description UM Type FB BIT Def Min Max Acc Mod
4770 First alarm UINT32 16 0 0 0 ERW
This parameter displays the rst alarm to be activated.
0 No alarm
1 Overvoltage
2 Undervoltage
3 Ground fault
4 Overcurrent
5 Desaturation
6 MultiUndervolt
7 MultiOvercurr
8 MultiDesat
9 Heatsink OT
10 HeatsinkS OTUT
11 Intakeair OT
12 Motor OT
13 Drive overload
14 Motor overload
15 Bres overload
16 Phaseloss
17 Opt Bus fault
18 Opt 1 IO fault
19 Opt 2 IO fault
20 Opt Enc fault
21 External fault
22 Speed fbk loss
23 Overspeed
24 Speed ref loss
25 Emg stop alarm
26 Power down
27 ExtIO fault
28 FastLink fault
29 Brake fault
30 Motor pre OT