11.2 Choke
11.2.1 Optional input chokes (L1) - (mandatory)
Sizes AFE200- AFE200
Mains
inductance
(µH)
Rated
current
(A)
Saturation
current
(A)
Type Code
3220-4
SP 1500 48 150 LR3-4-022-AFE S7AC5
SL 1200 60 100 LR3-4-030-AFE S7AL01
4450-4
SP / SL
715 94
290 LR3-4-045-AFE
S7AE7
5900-4 SP / SL 450 200 350 LR3-4-090-AFE S7AL02
61320-4 SP / SL 320 280 500 LR3-4-160-AFE S7AL03
71600-4
SP 320 280 500 LR3-4-160-AFE S7AL03
SL 210 430 900 LR3-4-250-AFE S7AL05
72000-4 SP / SL 210 430 900 LR3-4-250-AFE S7AL05
72500-4
SP 210
430 900
LR3-4-250-AFE
S7AL05
SL 180 530 1125 LR3-4-315-AFE S7AL06
73150-4/4A
SP 180 530 1125 LR3-4-315-AFE S7AL06
SL 150 600 1250 LR3-4-355-AFE S7AL04
73550-4/4A SP / SL 150 600 1250 LR3-4-355-AFE S7AL04
400kW
72000-4-MS
SP / SL
210 430 900 LR3-4-250-AFE S7AL05
72000-4-SL 210 430 900 LR3-4-250-AFE S7AL05
500kW
72500-4-MS
SP
210 430 900 LR3-4-250-AFE S7AL05
72500-4-SL 210 430 900 LR3-4-250-AFE S7AL05
500kW
72500-4-MS
SL
180 530 800 LR3-4-315-AFE S7AL06
72500-4-SL 180 530 800 LR3-4-315-AFE S7AL06
630kW
73150-4/4A-MS
SP
180 530 800 LR3-4-315-AFE S7AL06
73150-4/4A-MS 180 530 800 LR3-4-315-AFE S7AL06
630kW
73150-4/4A-MS
SL
150 600 1250 LR3-4-355-AFE S7AL04
73150-4/4A-SL 150 600 1250 LR3-4-355-AFE S7AL04
710kW
73550-4/4A-MS
SP / SL
150 600 1250 LR3-4-355-AFE S7AL04
73550-4/4A-SL 150 600 1250 LR3-4-355-AFE S7AL04
900kW
73150-4/4A-MS
SP
180 530 800 LR3-4-315-AFE S7AL06
73150-4/4A-SL 180 530 800 LR3-4-315-AFE S7AL06
73150-4/4A-SL 180 530 800 LR3-4-315-AFE S7AL06
900kW
73150-4/4A-MS
SL
150 600 1250 LR3-4-355-AFE S7AL04
73150-4/4A-SL 150 600 1250 LR3-4-355-AFE S7AL04
73150-4/4A-SL 150 600 1250 LR3-4-355-AFE S7AL04
1MW
73550-4/4A-MS
SP / SL
150 600 1250 LR3-4-355-AFE S7AL04
73550-4/4A-SL 150 600 1250 LR3-4-355-AFE S7AL04
73550-4/4A-SL 150 600 1250 LR3-4-355-AFE S7AL04