AFE200 • Instruction Manual 51
of the parameter (PAR).
When the parameter reached by the “Goto” command is displayed, it is possible
to navigate all the parameters forming part of the same group using the ▲ and ▼
keys.
Pressing the ► key returns to the “Goto” function.
To exit the “Goto” function, press the ► key.
6.3 Parameter modication
To enter parameter modication mode, press the E key when the parameter to be
modied is displayed.
To save the value of the parameter, following modication, press the E key again.
Note ! To save permanently, see paragraph 6.4.
To exit from modication mode without saving the value, press the ESC key.
The operations to be carried out to modify the value depend on the type of the
parameter, as described below.
Note ! For further information about the type of parameters displayed, see chapter 8.
● Numeric parameters
T+ T- EN LOC ILim n:0 AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
E
T+ T- EN LOC ILim n:0 AL
0 4 . 0 3
PA R : 1 2 0
In
p
ut inductance
0.7150
mH
Def: 0.715
T+ T- EN LOC ILim n:0 AL
0 4 . 0 3
PA R : 1 2 0
In
p
ut inductance
Def: 0.715
00000.7150
X 3
mH
When E is pressed to access modication mode, the cursor is activated on the
digit corresponding to the unit.
Using the ◄ and ► keys, the cursor can be moved to all the digits, including trail-
ing zeros that are normally not displayed.
With the ▲ and ▼ keys, the digit under the cursor is increased or decreased.
Press E to conrm the modication or ESC to cancel.
● Binary parameters (BIT type)
The parameter may assume only two states which are indicated as OFF-ON or
0-1.
X 5
T+ T- EN LOC ILim n:0 AL
05 REFERENCE
06 COMMANDS
07 DIGITAL INPUTS
08 DIGITAL OUTPUTS
E
T+ T- EN LOC ILim n:0 AL
0 8 . 0 5
PA R : 1 3 3 0
Di
g
out 1 inversion
ON
T+ T- EN LOC ILim n:0 AL
0 8 . 0 5
PA R : 1 3 3 0
Di
g
out 1 inversion
OFF
Pressing E, modication mode is activated. The entire line is displayed in reverse.
Use the ▲ and ▼ keys to move from one state to another.
Press E to conrm the modication or ESC to cancel.