38 AFE200 • Instruction Manual
5.3 Serial interface (XS connector)
XS
Funzione I/O Interfaccia elettr.
PIN 1
Uso interno
PIN 2
Uso interno
PIN 3
RxA/TxA I/O RS485
PIN 4
Equipotenzialità (opzionale)
PIN 5
0V (Ground for 5 V)
Alimentazione
PIN 6
Uso interno
PIN 7
RxB/TxB I/O RS 485
PIN 8
Uso interno
PIN 9
+5 V
Alimentazione
I = Ingresso
O = Uscita
The AFE200 drive is equipped as standard with a port (9-pin D-SUB connec-
tor: XS) for connection of the RS485 serial line used for drive/PC point-to-point
communication (through the GF-eXpress conguration software) or for multi-drop
connection.
To access the connector, remove the lower cover as illustrated in shown in para-
graph 5.2.1.
5.3.1 Drive / RS 485 Port (not insulated) point-to-point connection
The connection indicated is without galvanic insulation !
Le raccordement indiqué n’a pas d’isolation galvanique !
12
3
45
9 8 7 6
TxA/RxA
TxB/RxB
PE
+5 V
XS
Reserved
RS485
EQP
Figura 5.3.1.1: Serial connection (not insulated
A twin-pair consisting of two symmetrical conductors, spiral wound with a common
shield plus the bonding connection cable, connected as shown in the gure, must
be used for connection. The transmission speed is 38.4 kBaud.
For connection of the RS485 serial line to the PC, see the gure below.
The Modbus or Jbus serial protocol can be selected in the Serial protocol param-
eter PAR 3804. For more details see the “1S9H63_Modbus_it-en.pdf” instruction
manual in the CD supplied with the drive.
Caution