AFE200 • Instruction Manual 65
8 - Description of parameters and functions (Expert list)
Legend
Menu PAR Description UM Type FB BIT Def Min Max Acc
1 - MONITOR
1.1 250 Output current A FLOAT 16/32 0.0 0.0 0.0 R
1.2 252 Output voltage V FLOAT 16/32 0.0 0.0 0.0 R
13.2 - FUNCTIONS/DOUBLE PAR SET
13.2.1 3300 Par set enable ENUM Disable 0 1 ERW
13.2.2 3302 Par set select src LINK 16 6000 0 16384 ERWZ
L�DIGSEL2 (Selectionlist)[*]
(Level1menu)
(Level2menu)
Indexing of the menu and parameter
Parameter identifier
Parameter description
UM: unit of measure
Type of parameter
BIT Boolean, from modbus seen as 16 bits
ENUM Selection list, from modbus seen as 16 bits
FLOAT Real, from modbus seen as 32 bits
FBM2SIPA 16-bit unsigned integer. Only PAR of existing parame-
ters accepted.
FBS2MIPA 16-bit unsigned integer. Only PAR of existing parame-
ters accepted.
INT16 Integer with sign 16 bits, from modbus seen as 16 bits
INT32 Integer with sign 32 bits, from modbus seen as 32 bits
ILINK Selection list, from modbus seen as 32 bits
LINK Selection list, from modbus seen as 16 bits
UINT16 Integer without sign 16 bits , from modbus seen as 16 bits
UINT32 Integer without sign 32 bits, from modbus seen as 32 bits
Format of data exchanged on Fieldbus (16BIT, 32BIT)
Default value
Minimum value
Maximum value
Accessibility :
E Expert
R Read
S Size (set value depending on the size of the device)
W Write
Z parameters that can be modified ONLY with the
drive disabled
[*]
Selection lists:
The “... src” format parameters are linked to a selection
list.
The source of the signal that will control the parameter
can be selected from the list indicated.
The lists are indicated in paragraph 8.5 of this manual.