60 AFE200 • Instruction Manual
7.1 Startup Wizard
Introduction
The startup wizard is a guided procedure used for quick start-up of the drive that
helps to set the main parameters.
It consists of a series of questions relating to the various sequences for entering
and calculating the parameters necessary for correct drive operation.
The order of these sequences is as follows:
● Basic connections See step 1
● Setting of the capacitor value See step 2
● Setting of the choke value See step 3
● Setting of the DC-link parameters
See step 4
● Setting of application parameters (only if an application is installed)
● Saving parameters See step 5
The format of the function selection page is as follows:
T+ T- EN LOC ILim n:0 AL
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
Set capacitor value ?
E=Yes Down=Next
Pressing the E key, the function to be programmed is accessed.
Press the ▼ (Down) key to move to the next function skipping the current func-
tion.
Press the ▲ key to return to the previous function.
To terminate the sequence of functions and return to the menu, press the ESC
key.
The end of the start-up sequence is indicated with the page:
T+ T- EN LOC ILim n:0 AL
STARTUP WIZARD
End of se
q
uence !
U
p
=Back Down=Next
Press the ▼(Down) key to exit the sequence and return to the menu.