AFE200 • Instruction Manual 33
5.2 Regulation section
5.2.1 Removing the terminal cover
When removing the covers be carefull to lateral metal sheet enclosure. Presence of
sharp edge are possible.
A
A
5.2.2 Cable Cross Section
Terminal strips
(Regulation card)
Maximum Cable Cross Section Recommended stripping Tightening torque (min)
(min)
(mm
2
) (AWG) (mm) (Nm)
0.2 ... 2.5 24 ... 12 7 0.5
5.2.3 Regulation section connection
Figure 5.2.3.1: Regulation shielding
For shielding of the regulation section (recommended), fasten the shield of the
cables to the omega sections (see gure above).