AFE200 • Instruction Manual 169
Motore 3 : Im3 = 43A * 80% = 34,4A
Choose the size with the rated current required by the motor (≥ 34.4A) from the
catalogue ADV & AFE (section ADV200-DC “2.7 Output Data” on page 38).
With a 650 Vdc drive:
ADV-3220-...-DC (In = 41.4A, OK).
Drive Description Code Q.ty
ADV200-DC ADV-3185-KXX-4-DC S9O10DC 2
ADV200-DC ADV-3220-KXX-4-DC S9O11DC 1
Fuses for connection DC side S00C+/üf1/80/80A/690V F4EAF 6
AFE + components Description Code
AFE regenerative AFE200-4450-KXX-4 S9AF02 1
Line chokes LR3-4-045-AFE S7AE7 1
EMI lter EMI FN3120-480-80 S73EE 1
Pre-charge kit PRE CHARGE KIT-AFE-045-4 S726392 1
Fuses mains side connection S00C+/üf1/80/125A/690V F4EAJ 3
DC-Link total capacity:
(ADV-3185-KXX-4-DC * 2) 1500*2 + (ADV-3220-KXX-4-DC) 1500 + (AFE200-
4450-KXX-4) 3400 = 7900 μF
7900 μF ≤ 10000 μF +5% (OK)