10 VDL200 • Quick installation guide - Specifications and connection
The basic technical data of the inverter are included in the product code and data plate.
The inverter must be selected according to the rated current of the motor.
The rated output current of the drive must be higher than or equal to the rated current of the motor used.
The speed of the asynchronous motor depends on the number of pole pairs and frequency (plate and catalog data).
If using a motor at speeds above the rated speed, contact the motor manufacturer for any related mechanical problems
(bearings, unbalance, etc.). The same applies in case of continuous operation at frequencies of less than approx. 20 Hz
(inadequate cooling, unless the motor is provided with forced ventilation).
Name of model (code)
VDL 200 1 040 - X B L - F -4
Rated voltage:
4 = 400Vca, three-phase
EMI FILTER:
F = included
Lift application:
L = included
Braking unit:
X = not included
B = included
Keypad:
X = not included
Inverter power in kW:
040 = 4kW
055 = 5,5kW
075 = 7,5kW
110 = 11kW
150 = 15kW
185 = 18.5kW
220 = 22kW
Mechanical dimensions of the drive:
1 = size 1
2 = size 2
3 = size 3
Inverter, VDL200 series
Data plate
Type = Drive model; S/N = Serial number
Inp = Input (mains supply, frequency, AC Input
Current at constant torque)
Out = Output (Output voltage, frequency, power,
current, overload)
Approvals
Firmware and card revision plate
P = Power, R = Regulation
SW . CFG = Software revision
Prod CONF. = Product configuration
Position of plates on the drive