34 VDL200 • Quick installation guide - Specifications and connection
Connection to a PC with RS232 port (not isolated)
The following are required for connection:
• a shielded cable (cod. 8S864C L=4.5mt; cod. 8S874C L=10mt) for connection to the RS232 PC port of the drive to
Connection to a PC with USB port (not isolated)
The following are required for connection:
• an optional USB/RS232 adapter, code 8S8F62 (including the cable for USB connection)
• a shielded cable (cod. 8S864C L=4.5mt; cod. 8S874C L=10mt) for connection to the RS232 PC port of the drive to
7.5 Optional Keypad interface (keypad connector)
Keypad (XS1)connector
1
5
69
Several devices can be connected to the multifunction keypad connector (9-pin D-SUB receptacle connector XS1) and
are automatically recognised and managed.
1) Optional KB-ADL keypad (default connection)
- The keypad is supplied with a 40 cm-long cable,
for longer distances, a 1:1 non-crossover cable must be used (9
shielded cables, e.g. code 8S8F59, length 5 m).
- Very long cables (max. 15 m) must be of good quality with low voltage loss (max. 0.3 ohm/m).
2) I/F DCP protocol
-
Figure 7.5.3: DCP connection (not isolated)
The connections (1) and (2) have no galvanic isolation!
Caution