Page 23
CONTROL PROGRAMMING
Output speed rpm OPEN output speed
Output speed rpm
When a safety device is triggered, the
door moves at reduced speed.
Output speed in rpm
Up to an opening height of 2.5 m
0 = OFF
When a safety device is triggered, the
door moves at reduced speed.
Approach and store desired door position
(With adherence to minimum opening
height requirement of 2.5 m!)
Changeover position to
CLOSE output speed
OPEN deceleration
CLOSE deceleration
CLOSE acceleration
Setting for
DI in 1.0 s steps
FI in 0.1 s steps
OPEN acceleration
CLOSE output speed
Increased CLOSE
output speed
Settings only for ELEKTROMATEN
®
with direct / frequency converter DI/FI
4. Memorise 3. Adjustment
2. Choose program and
conrm
Press
selector
Press
selector
Press
selector
Press
selector
Press
selector
Press
selector
Press
selector
Press
STOP-
button
The appeared numbers for output speed OPEN and CLOSE corresponding to
the real RPM of the drive unit. The speed has a direct inuence into operating
forces of the door. The maximum and minimum speed will be delivered by the
drive unit in use and can not be raised or reduced.
Check again the adjustment and drive unit’s speed.
Setting for
DI in 1.0 s steps
FI in 0.1 s steps
Setting for
DI in 1.0 s steps
FI in 0.1 s steps
Setting for
DI in 1.0 s steps
FI in 0.1 s steps
OPEN/CLOSE crawling
speed
Press
selector
Output speed rpm
4.2
4.3
4.4
4.5
4.6
4. 1
4.7
4.8
4.9
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
-.-