Installation Installation
These hoods can be used with ELECTRIC FRYERS ONLY ... USE WITH GAS FRYERS IS NOT
APPROVED!! and can create an inhalation hazard due to carbon monoxide build‐up.
The following describes various appliance limitations and required clearances for appliances to be placed
underneath the hood. FSH‐2 & FSH‐2A‐99 ventless recirculating hoods are only listed for use with electric fryers
that comply with the following limitations.
ONLY
electrically heated fryers may be used ... Gas heated or equipment not meeting the specifications below are
not approved.
Model Max. Fryer kW
Max. Shortening
Capacity lbs [kg]
Max Cooking Surface
sq in [sq m]
FSH2PH 20 110 [49.9] 380 [.25]
2.04 Limitations & Clearances
2.04.1 Fryer Limitations