34
Operation
FSH-2-PH
4.04 E.A.C. Filter Cell Cleaning Timer Operation
The hood is equipped with a Filter Cell Cleaning Timer. This feature is intended to help users maintain a proper
cleaning routine for the sustainable E.A.C. Collector Cell. Timely cleaning is essential to ensure that the cleaning
system continues to effectively remove greaseladen cooking vapor particulate from the recirculated air.
After a preset period of time expires, the timer signals that it is time to clean the collector cell (or exchange it with a
clean standby cell, if available). If action is not taken within the alloted time, a timeout error alarm occurs and
power to the fryer is disabled and remains lockedout until filter maintenance is performed. After necessary
maintenance is performed, the timer automatically resets, a fresh countdown begins and normal operation is
restored.
Should error/alarm occur during a peak demand period or while cooking is in progress, a SNOOZE feature is
provided to temporarily postpone shutdown and continue operation for a short period of time.
Timer indicators and [SNOOZE] control button are located on the hood control box panel.
① CHANGE SOON
The amber indicator turns ON when timer enters [WARNING] mode. If the
collector cell is cleaned (or exchanged) within the next 24 hours, timer
automatically resets and begins a new countdown. Normal operation will
continue without interruption.
② CHANGE NOW
The red indicator turns ON when timer enters [TIMEOUT] error mode, signaling
that allowed time between cleanings has expired. An audible alarm sounds,
and fryer power is disabled. Power is locked out until cleaning (or exchange) is
completed. The hood [POWER]
and [FRYER POWER] lights will turn OFF.
Placing Power Switch in the [OFF] position silences the alarm. Hood cannot be
restarted unless the timer is reset by cleaning the cell.
Timer Operation:
1
2
NOTE: Does not apply to unit with HEPA Filter.
③ SNOOZE Button
In the event that [TIMEOUT] occurs during a period of high customer demand
or while a cooking cycle is in progress, the SNOOZE feature may be used to
exit [TIMEOUT] mode. Pressing the [SNOOZE] button temporarily returns
timer to [WARNING] mode for a period of two (2) hours, allowing continued
operation.
Only two (2) snooze periods are available. When a second is used, the
[CHANGE SOON]
light flashes to indicate this is the last snooze period. After
second period expires, fryer is once again lockedout until the E.A.C. cell is
cleaned (or exchanged).
NOTE: [SNOOZE] Button is only active after the timer enters [TIMEOUT] mode
and the red [CHANGE NOW] light is ON.
3