Operation
FSH-2-PH
If either the baffle, charcoal, or HEPA filters is not in place, or not positioned correctly, the red [FILTER
MISSING] light will turn ON. Power to the fryer under the hood is shutdown until the condition is
corrected; the amber [FRYER POWER] light turns OFF. No audible alarm will sound.
Hood fan continues running.
Check to confirm that all filters are in place. See Sections 4.02.3 4.02.5 4.02.6, Filter
Installations.
Remove and reinstall filters, ensuring that they are seated properly in the guides and are inserted
fully into the filter compartment so the cover fits properly. Each filter must also actuate a proofing
switch. Charcoal and HEPA filter switches are in the rear wall. Baffle filter switch is a lever switch
on the right side under the hood.
4.03 Hood Alarm Conditions
4.03.1 Filter Missing Baffle, Charcoal, or HEPA
If any filter becomes clogged or there are other conditions obstructing airflow that cause it to fall
below the minimum required to provide effective capture of cooking vapor, power to the fryer under
hood is shutdown, the amber [FRYER POWER] light turns OFF and a steady tone audible alarm sounds
until corrective action is taken.
Hood fan continues running.
Clean the baffle filter, see Section 4.04.1, Baffle Filter Cleaning.
Replace charcoal or HEPAfilter with fresh new, see Section 4.03.5, Charcoal Filter Maintenance.
Inspect Hood plenum to ensure that no other obstructions exist.
Check the hood exhaust outlet and be sure that nothing is obstructing it or the surrounding area.
4.03.2 Filter Clogged Baffle, Charcoal, or HEPA
NOTE: There is no indicator light for clogged filter, only an audible alarm.