Operator manual
Irregular functioning Possible cause Troubleshooting/Remedy
Door does not open Mains failure/emergency Check/replace
battery discharged the mains fuse
Operating mode Select AUTOMATIC
MANUAL/NIGHT operating mode
Defective control Make an opening attempt
element (sensor/radar/ with another control element
contact carpet, etc.) (outside/inside)
EMERGENCY STOP Release EMERG. STOP/
actuated if required carry out Reset
Door fails to close/ Operating mode Select AUTOMATIC
to close completely OPEN/MANUAL operating mode
Closing motion Remove obstacle
prevented (bottom guideway dirty?)
Manual unlocking Push the manual unlocking
has been actuated into the operating position
EMERGENCY STOP Release EMERG. STOP/
actuated if required carry out Reset
Object within the detection Remove the object
range of the sensor/
the light barrier
Redundant error Contact the after-
has been detected sales service
Door makes noises The bottom guideway Clean
islledwithdirt
Sliding wings produce friction Have the wings readjusted
on top or at the bottom by the after-sales service
Defective drive unit Contact after-
elements sales service
Door opening or Setting function Adjust according to
closing is too slow opening resp. closing speed chapter: Parameters
Insufcientopening Operatingmode SelectAUTOMATIC
width of the door AUTOMATIC (winter) (summer) operating mode
Setting function Adjust according to
reduced opening width chapter: Parameters
Insufcientorexcessive Settingfunction Adjustaccordingto
opening time hold-open time chapter: Parameters
Redundant error Contact after-
has been detected sales service
Option FLUVERI: Closing motion prevented Remove obstacle
Doorisnotlockedand Swingboltsinextendedposition Swingbacktheswingbolts
reopens Inclined position at the slid. wings Contact after-sales service
Option FLUVERI-A: Motor gear is not Select operating mode NIGHT
Upon actuation of the released and initiate 1...3 Key commands
unlocking lever, the door
is not automatically
opened
Option C-BEDIX: Key lockout activated Press the active key at least
switching-over is not during 5 seconds
possible
Option D-BEDIX: Key lockout activated Switch-off
switching-over is not
possible
6.3 Irregular functioning without error no.