User Manual
72
Parts
Torque
Cover screws 1.5-1.7 ft.lbs
Ground screws (Cover)
4.4-5.9 ft.lbs
AC terminals
17-21 ft.lbs
Ground screws (Internal)
7.4-8.9 ft.lbs
11. Appendices
Comments:
A thermal sensor inside the inverter is calibrated to determine ambient temperature.
All inverters will begin a sloped derate at 30°C ending at 78% output power at 60°C.
Temperatures above 60°C and below -25°C will derate to 0% output power.
11.1 Temperature Derating