NOTE: Use of a transformer is
recommended if installing a dual fuel/
fossil fuel system with a CTK01* or
CTK02*. Failure to use the transformer
in the outdoor unit could result in over
loading of the furnace transformer.
Follow the thermostat manufacturers
recommendation on when an outdoor
transformer is needed. Do not
attempt to install an outdoor
transformer when using an inverter
type unit.
COMFORTNET™ COMPATIBLE FURNACE
WITH
NON-COMFORTNET COMPATIBLE SINGLE-STAGE AIR CONDITIONER
Four wires are required between the furnace and thermostat. Two wires are required between the furnace control and single stage air
conditioner. For this system configuration, the “Y1” terminal on the integrated furnace control becomes an output rather than an
input. The “Y1” connection to the outdoor unit is made using both 4-position thermostat connectors in the CTK0* kit. Remove the
red keying tabs from the on-board connector block and position both 4-position connector such that “1”, “2”, “R”, “C”, and “Y1”
positions are filled.
NOTE: The cooling CFM for this in-
stallation must be set up at the com-
municating thermostat through
ComfortNet >furnace menu > non
com menu
COMFORTNET SYSTEM ADVANCED
FEATURES
The ComfortNet system permits access
to additional system information, ad-
vanced setup features, and advanced
diagnostic/troubleshooting features. These advanced features are organized into a menu structure. The menus are accessed and
navigated by means of the CTK0* thermostat. For details, see the thermostat instruction manual.
12RC
12RC
CTK0*
Thermostat
ComfortNet Compatible
Furnace Integrated
Control Module
ComfortNet Compatible
AC/HP Integrated
Control Module
40VA Transformer
208/230 VAC
24 VAC
12RC
System Wiring using Two-Wires between Furnace and AC/HP and Four-Wires between Furnace and
Thermostat
Figure 54
12RC
C Y
ComfortNet Compatible
Furnace Integrated
Control Module
CTK0*
Thermostat
Non- Compatible
Single Stage AC
ComfortNet
G
W1 W2 Y1 Y2
O
12RC
4-Position Connectors
from CTK0*
Thermostat Kit
System Wiring between Furnace and Non-Communicating Compatible Single Stage Air Conditioner
Figure 55