08 System Commissioning
User Manual V1.1-2022-12-20
8.2 Setting Inverter Parameters via SolarGo App
8.3 Monitoring via SEMS Portal
SEMS Portal is an monitoring platform used to communicate with the inverter via WiFi, LAN, 4G
or GPRS. Commonly used functions:
1. Manage the organization or User information;
2. Add and monitor the power plant information;
3. Equipment maintenance.
NOTICE
Please set the inverter parameters rst via SolarGo app to ensure its operation.
SEMS Portal
SolarGo app is a smart phone application used to communicate with the inverter via bluetooth,
WiFi, 4G or GPRS modules. Commonly used functions are as follows:
1. Check the operating data, software version, alarms, etc.
2. Set grid parameters, communication parameters, etc.
3. Equipment maintenance.
4. Upgrade software version.
For more details, refer to SolarGo User Manual. Scan the QR code or visit https://en.goodwe.
com/Ftp/EN/Downloads/User%20Manual/GW_SolarGo_User%20Manual-EN.pdf to get the user
manual.
SolarGo App
SolarGo App User Manual

Other manuals for Goodwe GW10K-ET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe GW10K-ET and is the answer not in the manual?

Goodwe GW10K-ET Specifications

General IconGeneral
ModelGW10K-ET
Max. DC Input Voltage1000 V
Number of MPPTs2
Rated AC Output Power10000 W
Max. AC Output Power11000 VA
Frequency50 Hz / 60 Hz
Efficiency98.3%
Dimensions516 x 415 x 180 mm
Weight25 kg
Max. DC Input Power13000 W
Start Voltage180 V
MPPT Voltage Range200V - 1000V
Number of MPP Trackers2
Max. Short Circuit Current per MPPT15 A
Nominal AC Output Power10000 W
Max. AC Apparent Power11000 VA
Nominal AC Voltage230 V / 400 V
Nominal Grid Frequency50 Hz / 60 Hz
THDi<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
Rated Output Power10000 W
Grid Frequency50 Hz / 60 Hz
Max. Efficiency98.3%
Noise Level<30 dB
Protection DegreeIP65
TypeThree Phase
AC Voltage Range180V - 280V
Power Factor0.8 leading - 0.8 lagging
Rated Grid Voltage230 V