02 Safety PrecautionUser Manual V1.1-2022-12-20
DANGER
Connect the DC cables using the delivered DC connectors and terminals.The manufacturer shall
not be liable for the equipment damage if other connectors or terminals are used.
WARNING
Ensure the component frames and the bracket system are securely grounded.
Ensure the DC cables are connected tightly, securely and correctly.
Measure the DC cables with a multimeter to avoid reverse polarity connection. Also, the
voltage should be under the permissible range.
Do not connect one PV string to more than one inverter at the same time. Otherwise, it may
cause damage to the inverter.
2 Safety Precaution
2.1 General Safety
2.2 PV String Safety
NOTICE
The information in this user manual is subject to change due to product updates or other
reasons. This guide cannot replace the product labels otherwise specied. All descriptions
in the manual are for guidance only.
Before installations, read through the user manual to learn about the product and the
precautions.
All operations should be performed by trained and knowledgeable technicians who are
familiar with local standards and safety regulations.
Use insulating tools and wear personal protective equipment when operating the
equipment to ensure personal safety. Wear anti-static gloves, clothes, and wrist strips
when touching electronic devices to protect the inverter from damage.
Strictly follow the installation, operation, and conguration instructions in this guide and
user manual. The manufacturer shall not be liable for equipment damage or personal
injury if you do not follow the instructions. For more warranty details, please visit https://
en.goodwe.com/warranty.
NOTICE
The inverters are designed and tested strictly in compliance with related safety rules. Read and
follow all the safety instructions and cautions before any operations. Improper operation might
cause personal injury or property damage as the inverters are electrical equipment.
Please strictly follow these safety instructions in the user manual during the operation.

Other manuals for Goodwe GW10K-ET

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe GW10K-ET and is the answer not in the manual?

Goodwe GW10K-ET Specifications

General IconGeneral
ModelGW10K-ET
Max. DC Input Voltage1000 V
Number of MPPTs2
Rated AC Output Power10000 W
Max. AC Output Power11000 VA
Frequency50 Hz / 60 Hz
Efficiency98.3%
Dimensions516 x 415 x 180 mm
Weight25 kg
Max. DC Input Power13000 W
Start Voltage180 V
MPPT Voltage Range200V - 1000V
Number of MPP Trackers2
Max. Short Circuit Current per MPPT15 A
Nominal AC Output Power10000 W
Max. AC Apparent Power11000 VA
Nominal AC Voltage230 V / 400 V
Nominal Grid Frequency50 Hz / 60 Hz
THDi<3%
DC SwitchYes
Protection ClassIP65
Operating Temperature Range-25°C to +60°C
Cooling MethodNatural Convection
Rated Output Power10000 W
Grid Frequency50 Hz / 60 Hz
Max. Efficiency98.3%
Noise Level<30 dB
Protection DegreeIP65
TypeThree Phase
AC Voltage Range180V - 280V
Power Factor0.8 leading - 0.8 lagging
Rated Grid Voltage230 V